Fault codes Vaillant

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

Sometimes a number follows the code (6A 227): type it too, the page shows what it means.

Your brand

Your boiler Vaillant

The model is written on the rating plate, often under the cover.

All codes Vaillant

F.00 Flow temperature sensor disconnected
F.01 Return temperature sensor disconnected
F.02 Hot water sensor disconnected
F.03 Cylinder temperature sensor disconnected
F.040 Air ratio too low
F.044 Flame signal too weak
F.05 Outer flue gas sensor disconnected
F.087 Ignition not connected to the circuit board
F.088 Gas valve not connected
F.089 Heating pump incompatible or badly connected
F.095 Gas valve at its minimum limit
F.096 Gas valve at its maximum limit
F.10 Flow temperature sensor short circuit
F.103 Spare part not recognised
F.105 Gas valve setting to be redone
F.11 Return temperature sensor short circuit
F.110 No ignition with the enriched mixture
F.1100 Back-up heater overheat cut-out tripped
F.1101 Flow too hot during back-up heating
F.1117 Compressor phase failure
F.1118 Compressor: wrong phase sequence
F.1119 Compressor: starting current limiter fault
F.1120 Back-up heater phase failure
F.1191…F.1195, F.1200…F.1211, F.1252…F.1255 Heat pump or boiler: connection lost
F.12 Hot water sensor short circuit
F.1212…F.1214 FM3 module: connection lost
F.1218 FM5 module: connection lost
F.1219…F.1222 Remote control: connection lost
F.1227 Domestic hot water station: connection lost
F.1228, F.1229 Solar station: connection lost
F.1231…F.1233 FM3 module set up wrongly
F.1237 Mixing module not supported
F.1238 Solar module not supported
F.1239 Remote control not supported
F.1240 System schematic code incorrect
F.1244 FM3 module missing
F.1245 Hot water sensor S1 missing on FM3
F.1246, F.1247 Solar pump reports a fault
F.1248 Stratification cylinder not supported
F.1249 Heat pump control module configuration incorrect
F.1251 FM5 module set up wrongly
F.1257…F.1259 FM3 multi-function output set wrongly
F.1263 FM5 multi-function output set wrongly
F.1288 SP1 cylinder temperature sensor fault
F.13 Cylinder temperature sensor short circuit
F.1350 Communication with the central control unit lost
F.1361 System control room sensor faulty
F.1363…F.1366 Remote control room sensor faulty
F.1371 Storage cylinder temperature sensor (SP1) invalid
F.1372 System temperature sensor (VF1) invalid
F.1373 Outdoor temperature sensor (AF) invalid
F.1374 Heating pump faulty
F.1379 Separation valve not closing during self-test
F.1492 Refrigerant detected in the water circuit
F.15 Outer flue gas sensor short circuit
F.1513 Flow sensor signal invalid
F.1514 Communication with the flow sensor lost
F.1515 Flow temperature too high
F.1522 Multi-function temperature sensor 1 (MT1) invalid
F.1523 Multi-function temperature sensor 2 (MT2) invalid
F.1524 Primary circuit flow sensor fault
F.16 Inner flue gas sensor short circuit
F.194 Circuit board power supply faulty
F.195 Supply voltage too low
F.196 Supply voltage too high
F.20 Overheat safety device tripped
F.2022 Hydraulic circuit pressure sensor invalid
F.22 Not enough water or water pressure too low
F.228 Ignition failed in emergency mode
F.229 Re-ignition failed in emergency mode
F.23 Flow-return temperature difference too large
F.235 Flue blocked at first start-up
F.24 Temperature rising too fast
F.25 Flue gas temperature too high
F.26 Gas valve fault
F.27 Flame detected with the burner off
F.279 Hot gas temperature too high
F.28 Ignition failure at start-up
F.281 Flame lost during stabilisation
F.283 Outdoor unit defrost failed
F.29 Flame lost during operation, relighting failed
F.291 Flame lost again during stabilisation
F.317 Hot water flow sensor signal implausible
F.318 Three-way valve does not move
F.32 Fan not running correctly
F.320 Heating pump blocked
F.321 Pump electronics faulty
F.322 Heating pump overheating
F.323 Heating pump running dry
F.324 Pump electrical connection cut
F.325 Heating pump fault
F.326 Two hydraulic components not working
F.327 Hot water circuit not connected or blocked
F.33 Air pressure switch fault
F.330 Pump not responding during the test
F.334 Flue configuration not completed
F.336 Configuration not approved for this boiler
F.337 Shared flue conversion kit not compatible
F.338 Multiple flue setting wrong
F.34 Safety shutdown by pressure monitoring
F.342 Air flow outside the allowed limits
F.343 Air flow sensor signal invalid
F.344 Control electrode unusable
F.347 Condensate in the combustion chamber
F.35 Air and flue duct blocked
F.36 Flue gas detected outside the flue
F.363 Display memory error
F.37 Fan off target or faulty
F.42 Coding resistor fault
F.43 Coding resistor open circuit
F.45 Cold water inlet sensor fault
F.46 Cold water inlet sensor short circuit
F.47 Hot water outlet sensor fault
F.48 Hot water outlet sensor short circuit
F.49 eBUS line fault (controls)
F.50 Flue gas pressure switch tripped
F.5000…F.5020 FM3 module sensor faulty
F.5021…F.5033 FM5 module sensor faulty
F.5034…F.5049 Heat pump or boiler reports a fault
F.504 Fan 1 fault: signal or speed
F.5050 Ventilation unit reports a fault
F.5051 Heat pump control module reports a fault
F.5056…F.5059 Remote control not assigned to a zone
F.5060 Zone in use not activated
F.509 Ventilation unit: connection lost
F.51 Fault detected by the flue gas sensor
F.511 Heat pump control module: connection lost
F.514 Compressor inlet temperature sensor fault
F.517 Compressor outlet temperature sensor fault
F.519 Return temperature sensor fault
F.52 Mass flow sensor not connected
F.520 Flow temperature sensor fault
F.521 Outdoor temperature sensor faulty
F.523 VF1 temperature sensor fault
F.526 Expansion valve temperature sensor fault
F.53 Gas flow outside expected values
F.532 Heating circuit flow rate too low
F.536 Compressor outlet temperature too high
F.537 High-pressure switch open
F.539 Refrigerant pressure too low
F.54 Gas pressure too low at start-up
F.546 High-pressure sensor fault
F.55 CO sensor fault
F.554 Refrigerant pressure outside operating range
F.56 Safety shutdown: CO limit exceeded
F.57 Combustion control fault
F.582 Electronic expansion valve fault
F.583 Heating flow temperature too low
F.585 Condenser outlet temperature sensor fault
F.6 Inner flue gas sensor disconnected
F.60-67 Fault in the boiler electronics
F.61 Gas valve control fault
F.6103 Primary circuit pressure not available
F.6104 Primary circuit pressure too low
F.6105 Heating circuit water pressure not available
F.6106 Heating circuit water pressure too low
F.6107 Hot water cylinder temperature not available
F.6111 No heat generator available
F.6181 Communication with the indoor unit lost
F.6182 Communication with the outdoor unit lost
F.6183 Communication with the function module lost
F.62 Delayed gas valve shut-off
F.63 Circuit board memory (EEPROM) fault
F.64 Electronics or sensor fault
F.65 Electronics temperature too high
F.67 Implausible flame signal
F.68 Unstable flame signal
F.685 Communication lost with the system control
F.70 Invalid appliance identification
F.701 Brine inlet temperature sensor fault
F.702 Brine outlet temperature sensor fault
F.703 Refrigerant circuit low-pressure sensor fault
F.704 Heating circuit pressure sensor fault
F.705 Brine circuit pressure sensor fault
F.707 No communication between display and circuit board
F.708 Fan module 1: connection lost
F.71 Flow sensor stuck on one value
F.710 Brine too cold at the outlet
F.714 Brine circuit pressure too low
F.715 Brine circuit pump fault
F.718 Fan 1 blocked, not turning
F.719 Fan module: overheat safety open
F.72 Flow and return sensor mismatch
F.723 Heating circuit pressure too low
F.724 Fan module 1: air inlet sensor fault
F.725 Fan module 1: brine flow sensor fault
F.727 Refrigerant circuit high-pressure monitoring tripped
F.728 Refrigerant circuit low-pressure monitoring tripped
F.729 Compressor outlet temperature too low
F.73 Water pressure sensor: signal too low
F.731 High-pressure switch tripped
F.732 Compressor outlet temperature too high
F.733 Evaporation temperature too low
F.734 Condensing temperature too low
F.735 Evaporation temperature too high
F.737 Condensing temperature too high
F.739 Not enough refrigerant
F.74 Water pressure sensor: signal too high
F.740 Brine too cold for compressor start
F.741 Heating return too cold
F.742 Brine too warm for compressor start
F.743 Heating return too hot for compressor start
F.75 Pump fault or lack of water
F.750 Compressor connection fault
F.751 Compressor current too high
F.752 Compressor inverter fault
F.753 Compressor inverter not detected
F.754 Fan module fault
F.755 4-way valve in the wrong position
F.757 Compressor minimum run time missed too often
F.758 Compressor problem detected by the inverter
F.759 Inverter internal sensor fault
F.76 Heat exchanger overheat protection tripped
F.761 Inverter current too high
F.762 Abnormal voltage detected by the inverter
F.764 Compressor phase error (inverter)
F.77 Flue gas flap or condensate pump fault
F.774 Air inlet temperature sensor fault
F.78 Accessory or control module misconfigured
F.782 Fan module 2: connection lost
F.783 Mains connection board: connection lost
F.784 Starting current limiter: connection lost
F.785 Fan 2 blocked, not turning
F.786 Fan module 2: overheat safety open
F.787 Brine circuit pressure switch open
F.788 Heating circuit pump fault
F.789 Fan module 2: air inlet sensor fault
F.790 Fan module 2: brine flow sensor fault
F.792 Refrigerant circuit temperature sensor fault
F.793 Refrigerant circuit temperature sensor fault
F.797 Cooling flow temperature sensor fault
F.798 Well inlet temperature sensor fault
F.799 Well outlet temperature sensor fault
F.80 Storage tank inlet sensor fault
F.801 Frost protection not guaranteed
F.802 Exhaust air fan fault
F.803 Supply air fan fault
F.804 Supply air too cold
F.805 Incoming air too hot
F.806 Frost protection element fault
F.807 Supply air pressure sensor failure
F.808 Exhaust air pressure sensor failure
F.809 Outdoor air temperature sensor failure
F.81 Storage tank charging failed
F.810 Exhaust air temperature sensor failure
F.811 Supply air temperature sensor failure
F.812 Extract air temperature sensor failure
F.813 Extract air fan undersized
F.814 Supply air fan undersized
F.815 Extract air humidity sensor fault
F.816 Fan connections swapped
F.817 Compressor fault reported by the inverter
F.818 Inverter mains voltage out of tolerance
F.819 The inverter has overheated
F.82 Impressed current anode fault
F.820 No communication with heating pump
F.821 Back-up heater flow sensor fault
F.822 Glycol circuit pressure sensor fault
F.823 Compressor hot gas thermostat tripped
F.824 Decoupled glycol circuit pressure too low
F.825 Condenser inlet sensor fault
F.827 Heating water pressure sensor fault
F.828 Refrigerant circuit service opening open
F.829 Refrigerant circuit service opening sensor fault
F.83 Temperature does not rise at burner start
F.84 Implausible flow-return temperature difference
F.842 Incorrect heat pump configuration
F.85 Flow and return sensors wrongly fitted
F.86 External safety contact open (underfloor heating)
F.90 Communication with the tank module lost
F.900 Internet module: connection lost
F.905 Communication interface switched off
F.91 Storage module sensor fault
F.92 Gas type setting not valid
F.93 Combustion quality out of range
F.94 Vortex sensor fault
F.97 Main circuit board self-test failed
F.9997 Indoor and outdoor units do not match
F.9998 No link with the outdoor unit
I.003 Appliance service due
I.020 Low heating water pressure
I.023 Impressed current anode signal invalid
I.032 Low water pressure in the heating circuit
I.144 Flame control electrode worn
I.200 Low pressure in the decoupled glycol circuit
I.201 Cylinder temperature sensor fault
I.202 System temperature sensor fault
I.203 Display not linked to the main circuit board
I.6104 Low pressure in the primary circuit
I.6106 Heating circuit water pressure low
L.016 Flame lost at minimum power
L.022 Too little water circulating in the heating
L.025 Cold water inlet sensor short-circuited
L.032 Flow sensor faulty or signal implausible
L.095 Gas valve at its lower control limit
L.096 Gas valve at its upper control limit
L.097 Not enough air for combustion
L.105 Boiler air venting not completed
L.1307 Requested electrical power not reached
L.1380 Flow and return sensor calibration failed
L.144 Flame signal too weak at the control electrode
L.194 Circuit board power supply failing
L.195 Supply voltage too low
L.196 Supply voltage too high
L.250 Fan 1 speed setpoint not reached
L.251 Fan 2 target speed not reached
L.255 Air inlet temperature too high
L.256 Air inlet temperature too low
L.271 Heating circuit water flow too low
L.273 Flow temperature too low, waiting time
L.275 Water flow too low during defrosting
L.283 Defrost failed, trying again
L.284 Flow temperature too low during defrosting
L.287 Fan 1 speed too high
L.302 Refrigerant circuit high-pressure switch tripped
L.303 Waiting time: compressor outlet too hot
L.304 Waiting time: evaporation temperature too low
L.305 Waiting time: condensation temperature too low
L.306 Waiting time: evaporation temperature too high
L.308 Waiting time: condensation temperature too high
L.312 Return temperature too low
L.314 Return temperature too high
L.319 Boiler internal bypass blocked
L.320 Heating pump blocked
L.321 Pump electronics not available
L.322 Pump electronics overheating
L.323 Heating pump running dry
L.343 Air flow sensor signal invalid
L.351 Electric back-up heater flow temperature too high
L.42 Coding resistor temporarily invalid
L.504 Fan 1 signal or speed invalid
L.6108 Underfloor heating contact thermostat tripped
L.6150 Communication with EEBUS unit or energy manager lost
L.718 Fan 1 not turning, restarting
L.729 Compressor outlet superheat too low
L.739 Refrigerant charge low
L.745 Water flow setting too high
L.752 Inverter or compressor internal fault
L.753 Communication with the inverter interrupted
L.755 4-way valve not in the expected position
L.757 Minimum compressor run time not reached
L.758 Compressor status invalid, restarting
L.759 Internal inverter sensor signal invalid
L.761 Current too high inside the inverter
L.762 Unusual voltage detected, restarting
L.763 Compressor speed differs from the setpoint
L.764 Inverter reports a compressor phase error
L.785 Fan 2 not turning, restarting
L.788 Heating circuit pump internal fault
L.817 Compressor motor fault reported
L.818 Mains voltage absent or out of tolerance
L.819 Inverter overheating, restarting
L.823 Compressor temperature switch tripped
M.200 Low glycol pressure in heating circuit
M.201 Cylinder temperature sensor faulty
M.202 System temperature sensor faulty
M.203 Display not detected, link fault
M.23 Impressed current anode not detected
M.32 Heating water pressure low
M.33 Fan module needs cleaning
M.34 Low brine circuit pressure
M.49 Brine pipes swapped
M.800 Ventilation filters due for service
M.801 Unit service overdue
M.802 System efficiency reduced
N.013 Water pressure sensor signal invalid
N.027 Hot water temperature sensor signal implausible
N.032 Flow sensor faulty or signal implausible
N.089 Heating pump not matching the boiler type
N.095 Gas valve at its lower control limit
N.096 Gas valve at its upper control limit
N.097 Not enough air for combustion
N.100 Outdoor temperature sensor signal lost
N.144 Flame signal too weak at the control electrode
N.194 Circuit board power supply failing
N.200 Outdoor unit air inlet sensor fault
N.270 Hot water side temperature difference too high
N.317 Hot water flow sensor signal implausible
N.319 Boiler internal bypass blocked
N.324 Pump electrical connection broken
N.343 Air flow sensor signal invalid
N.521 Outdoor temperature sensor fault
N.6100 Heat pump out of order
N.6101 Outdoor temperature not available
N.6102 Back-up heater flow temperature not available
N.6109 No back-up heater available
N.685 Communication with the system control interrupted
N.820 Communication with the heating pump lost
S.00 No heating demand
S.01 Heating: fan starting
S.012 Hot water draw-off: pump pre-run
S.019 Hot water draw-off with automatic adjustment
S.02 Heating: pump starting
S.03 Heating: burner ignition
S.04 Heating: burner on
S.05 Heating: pump and fan run-on
S.06 Fan run-on in heating mode
S.07 Pump run-on in heating mode
S.08 Burner off-time in heating mode
S.09 Heating with automatic measuring or adjustment
S.10 Hot water demand at the tap
S.100 Heat pump on standby
S.101 Heating: compressor switched off
S.102 Heating: compressor blocked
S.103 Heating: preparing to start
S.104 Heating: compressor running
S.105 Low flow: run purge P00 again
S.107 Heating: pump and fan overrun
S.108 Purge operation in progress
S.109 Standby mode active
S.11 Hot water draw-off: fan starting
S.111 Cooling: compressor switched off
S.112 Cooling: compressor blocked
S.113 Cooling: preparing to start
S.114 Cooling: compressor running
S.117 Cooling: pump and fan overrun
S.118 Cooling mode pre-run
S.119 Cooling with mixing valve active
S.125 Heating: electric back-up heater on
S.13 Hot water draw-off: burner ignition
S.131 Hot water, compressor off
S.132 Hot water: compressor blocked, outside operating limits
S.133 Hot water: pre-run before the compressor starts
S.134 Hot water: compressor running
S.135 Hot water: electric back-up heater on
S.137 Hot water: overrun after heating
S.14 Hot water draw-off: burner on
S.141 Heating: electric back-up heater switched off
S.142 Heating: electric back-up heater blocked
S.15 Hot water draw-off: pump and fan run-on
S.151 Hot water: electric back-up heater switched off
S.152 Hot water: electric back-up heater blocked
S.16 Hot water draw-off: fan run-on
S.17 Hot water draw-off: pump run-on
S.170 Compressor phase failure
S.171 Wrong compressor phase sequence
S.172 Compressor starting current limiter fault
S.173 Power cut by the electricity supplier
S.175 Installation assistant running
S.176 External electrical power limit active
S.199 Automatic filling in progress
S.20 Hot water demand: cylinder or keep-warm
S.201 Brine circuit venting program running
S.202 Heating circuit venting program running
S.203 Sensor and actuator test running
S.204 Compressor oil return in progress
S.21 Hot water cylinder: fan starting
S.211 Heat pump display not detected
S.212 Connection to the system control lost
S.213 Fan module 1 not detected
S.214 Fan module 2 not detected
S.215 Mains terminal board not detected
S.216 Starting current limiter not detected
S.22 Hot water cylinder: pump pre-run
S.23 Hot water cylinder: burner ignition
S.24 Hot water cylinder: burner on
S.240 Compressor oil too cold: waiting
S.242 Brine outlet temperature too low
S.246 Brine circuit pressure too low
S.247 Brine pump fault signal
S.248 Fan module defrosting with fan only
S.249 Fan module defrosting with defroster
S.25 Hot water cylinder: pump and fan run-on
S.252 Fan unit 1: fan blocked
S.253 Fan module 1 overheat cut-out open
S.254 Fan module 1 defrosting too long
S.255 Outdoor air too warm to run
S.256 Outdoor air too cold to run
S.26 Hot water cylinder: fan run-on
S.260 Fan unit 2: fan blocked
S.261 Fan module 2 overheat cut-out open
S.262 Fan module 2 defrosting too long
S.263 Fan module 2 air inlet too hot
S.264 Fan module 2 air inlet too cold
S.265 Brine circuit pressure switch open
S.266 Brine outlet temperature too high
S.27 Hot water cylinder: pump run-on
S.272 Heating pump pressure limit reached
S.273 Heating flow temperature too low
S.274 Heating water pressure too low
S.275 Flow too low in the heating circuit
S.276 Safety contact S20 open
S.277 Heating circuit: pump fault
S.278 Flow temperature too high for the heat pump
S.279 Outside operating range: hot gas monitoring tripped
S.28 Hot water cylinder: burner off-time
S.280 Inverter fault: compressor
S.281 Inverter fault: mains voltage
S.282 Inverter fault: overheating
S.283 Defrost time too long
S.284 Flow temperature too low during defrost
S.285 Compressor outlet temperature too low
S.286 Hot gas thermostat tripped
S.287 Fan 1 turned by the wind
S.288 Fan 2 turned by the wind
S.289 Compressor current limit active
S.29 Hot water cylinder with automatic adjustment
S.290 Start delay active
S.30 Heating blocked by the room thermostat
S.302 High-pressure switch open
S.303 Compressor outlet temperature too high
S.304 Evaporation temperature too low
S.305 Condensation temperature too low
S.306 Waiting: evaporation temperature too high
S.308 Waiting: condensing temperature too high
S.31 Summer mode or no demand from the controller
S.311 Brine inlet temperature too low
S.312 Heating return too cold to start
S.313 Brine inlet temperature too high
S.314 Heating return too hot to start
S.32 Waiting: fan speed out of tolerance
S.326 Hydraulic sensor and actuator test
S.328 External pump running permanently
S.33 Waiting: air pressure switch not switched
S.335 Flue blockage test
S.34 Frost protection active
S.341 Output reduced after a long burner run
S.35 Waiting: fan blocked, abnormal speed
S.350 Back-up heater overheat cut-out open
S.351 Flow too hot at the back-up heater
S.352 Pressure too low for back-up heater
S.353 Flow too low for back-up heater
S.354 Back-up heater phase failure
S.36 Controller setpoint below 20 °C
S.37 Waiting: fan fault during operation
S.39 Burner blocked by a contact thermostat
S.40 Comfort safety mode: reduced heating
S.41 Water pressure too high
S.42 Burner blocked by the flue gas flap
S.44 Return sensor: comfort safety mode
S.46 Comfort safety mode: flame lost at minimum load
S.47 Comfort safety mode: flame lost at maximum load
S.48 Comfort safety mode: fan speed deviation
S.49 Waiting time after a pressure switch tripped
S.51 Flue gas escape detected, tolerance time
S.516 Outdoor unit defrosting
S.52 20-minute wait after flue gas escape
S.53 Waiting time due to water shortage
S.54 Waiting time: water shortage, temperature rising too fast
S.55 Waiting time: CO sensor
S.56 Waiting time after CO limits were exceeded
S.57 Waiting time set by the combustion control
S.575 Inverter internal fault
S.58 Burner output limited
S.581 Inverter not detected, link fault
S.59 Water flow too low to start
S.590 4-way valve in wrong position
S.599 The boiler reports a fault
S.60 Waiting time after flame loss
S.61 Gas check: wrong circuit board coding
S.62 Gas check: CO2 adjustment needed
S.63 Gas check failed: check the gas line
S.727 High-pressure monitoring tripped, restarting
S.728 Low-pressure monitoring tripped, restarting
S.76 Water pressure too low, top up
S.800 Frost protection element active
S.802 Heat recovery active
S.803 Heat recovery off
S.804 Heat recovery at 50%
S.805 Ventilation in automatic mode
S.806 Ventilation in manual mode
S.807 Intensive ventilation on
S.808 Calibration mode active
S.809 Check program or sensor test running
S.810 Away mode on
S.811 Moisture protection active
S.812 Standard frost protection active
S.813 Bypass anti-seize function running
S.814 Run-on after intensive ventilation
S.815 Unit off for frost protection
S.816 Ventilation emergency stop on
S.85 Water flow too low, maintenance message
S.86 Maintenance message: check the vortex sensor
S.87 Maintenance message: check the differential pressure sensor
S.88 Air purge programme running
S.91 Demonstration mode active
S.92 Water circulation self-test
S.93 Flue gas measurement not possible yet
S.96 Return sensor self-test
S.97 Water pressure sensor self-test
S.98 Flow and return sensor self-test
S.99 Self-test, filling or pipe length adaptation
con No communication between display and circuit board
200 Air inlet sensor fault, reduced comfort
500 Heat pump waiting
501 Pump pre-run before heating
502 Pump pre-run correct in heating mode
503 Water temperature check before heating
504 Heating mode starting
505 Pump pre-run at full speed for heating
506 Fan pre-run in heating mode
507 4-way valve in heating position
508 Electronic expansion valve in heating position
509 Compressor start requested for heating
510 Heat pump in heating mode
511 Heat pump in hot water mode
512 Heating: water temperature exceeded
513 Hot water: water temperature exceeded
514 Pump overrun after heating
515 Pump pre-run before defrosting
516 Heat pump defrosting
517 Pump overrun after defrosting
518 Pump controlled remotely (back-up)
519 Compressor oil temperature too low
530 Pump pre-run before cooling
531 Pump pre-run correct in cooling mode
532 Water temperature check before cooling
533 Cooling mode starting
534 Pump pre-run at full speed
535 Fan pre-run under way
536 4-way valve in cooling position
537 Electronic expansion valve in cooling position
538 Compressor start requested for cooling
539 Heat pump in cooling mode
540 Cooling: water temperature exceeded
541 Pump overrun after cooling
550 Pressure equalisation error
551 Pressure switch error
552 Operating pressure error detected
553 Operating pressure not correct at start-up
554 Off-peak power supply cut
555 Refrigerant circuit: pressure ratio too low
556 Refrigerant circuit: condensation too low
557 Refrigerant circuit: evaporation too high
558 Refrigerant circuit: condensation too high
559 Refrigerant circuit pressure too low
560 Compressor outlet overheating
561 Compressor inlet temperature sensor error
562 Compressor outlet temperature sensor error
563 Plate heat exchanger sensor error
564 Finned heat exchanger sensor error
565 Outdoor temperature sensor error
566 Flow temperature sensor error
567 Return temperature sensor error
568 Refrigerant circuit high pressure sensor error
569 Inverter: low voltage bus error
570 Inverter switched off
571 Inverter overheating error
572 Inverter overcurrent error
573 Inverter voltage too low
574 Inverter voltage too high
575 Internal inverter error
576 Inverter heating sensor error
577 Inverter overload error
578 Fan circuit board error
579 eBus communication error
580 Flow rate error
581 Inverter communication error
582 Compressor overcurrent fault
584 Electronic expansion valve error
585 Fan speed too low
588 Coding resistor fault
589 Underfloor heating protection circuit error
590 4-way valve error
599 Heat pump error