Fan off target or faulty
Breakdown: the boiler is stopped
During operation, the fan runs too fast or too slow compared with its target (ecoVIT VKK, ecoCOMPACT VSC); on the ecoVIT VKK /5, the boiler switches to emergency mode after a passing problem in the air circuit. It is a fault: the boiler no longer works normally and needs a technician. On an aroTHERM heat pump VWL 55/2 A to 155/2 A or VWL 55/3 A and 85/3 A, F.37 reports a fault of the outdoor unit's fan: air duct blocked, fan motor faulty or not connected, or the link between the main circuit board and the fan circuit board broken; here too our technician needs to step in.
What you can do
- Write down the code shown and the boiler or heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.37?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a recognised installer
Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.
The variants of code F.37
The meaning depends on the boiler: find yours below.
Fan error
Fault Fan speed deviation
Emergency mode, minimum speed increased
Fan speed too high or too low during operation
What our technician checks
- The fan connector and wiring harness
- The pressure sensor
- The fan and the circuit board
- ecoVIT VKK /5: the air circuit
- aroTHERM VWL ../2 A, ../3 A: the unit's air duct, free of obstacles
- aroTHERM VWL ../2 A, ../3 A: the fan motor and its connection
- aroTHERM VWL ../2 A, ../3 A: the link between the main circuit board and the fan circuit board