Maintenance
Servicing your appliances, at the displayed price
Tick your appliances, choose the moment: a certified technician comes, the official certificate arrives by e-mail.
Schedule my maintenance+32 2 771 40 43
Already a customer? Sign in to see your appliances
Our prices
Per appliance, travel included. Several appliances: one visit, the prices add up.
A boiler over 75 kW is quoted on site. A part replaced is invoiced on top, after your agreement.
What the law says
The legal minimum; we advise a maintenance every year.
Brussels
Gas boiler: inspection every 2 years. Oil: every year. By a technician certified by Brussels Environment, who records the official certificate. In a rental, the tenant arranges it, unless the lease says otherwise.
Flanders
Boiler of 20 kW or more: gas every 2 years, oil every year, by a certified technician. The certificate lands in your Woningpas. A boiler refused at inspection and still in use can cost you your fire insurance.
Wallonia
Gas boiler up to 100 kW: inspection every 3 years, every 2 years beyond. Oil: every year. By a certified technician, who gives you the certificate; keep the last two.
Heat pump
No legal inspection as for a boiler, except for a large refrigerant charge. But most manufacturers require servicing to keep the warranty beyond the 2 legal years.
Sources: Brussels Environment (19/01/2025), vlaanderen.be (read on 09/11/2026), Walloon Government Decree of 29/01/2009 (art. 13), Regulation (EU) 2024/573 on fluorinated gases.
Why service
19
deaths a year in Belgium
Carbon monoxide is the first cause of fatal accidental poisoning. In Brussels, 2 to 3 people are poisoned every week, mostly by poorly maintained heaters and water heaters.
Poison Centre, 2018 to 2023 average; be.brussels, 15/10/2025
+5 %
more consumption
A poorly maintained boiler uses about 5% more: a well-tuned burner shows straight on the bill.
2 years
of legal warranty, without proof of servicing
Without proof of servicing, the warranty often stops there. Vaillant grants its 3 extra years only to a serviced appliance, Viessmann asks for a maintenance contract.
What we check at each maintenance
The points of the sheet our technicians fill in at every visit, one by one.
Appliance servicing
- General condition checked: cleanliness, tightness, wear, operation
- Casing and electronics dusted
- Burner cleaned
- Electrodes cleaned and set
- Heat exchanger cleaned
- Condensate drain checked, siphon cleaned and filled
- Burner set to the manufacturer's values
Flue and air
- Flue checked and cleaned, or the sweep's certificate seen
- Combustion air duct checked (room-sealed appliance)
Hydraulics and controls
- Circulator works
- Thermostat talks to the boiler
- Valves and air vents work, no leak
Safety
- Measuring ports sealed again
- Safety devices
The measurement
With the analyser, not by eye.
- Combustion analysed before and after the work
- CO, efficiency and flue gas temperature
- Compared with the legal limits of your region
- The analyser's report kept as proof
- Ambient CO measured on arrival and in front of the appliance
Appliance servicing
- General condition checked: cleanliness, tightness, wear, operation
- Casing and electronics dusted
- Burner cleaned: fan, combustion head, flame detector
- Nozzle checked
- Oil filter cleaned
- Electrodes cleaned and set
- Pump pressure checked and set
- Heat exchanger cleaned
- Condensate drain checked, siphon cleaned and filled
- Burner set to the manufacturer's values
Flue and air
- Flue checked and cleaned, or the sweep's certificate seen
- Combustion air duct checked (room-sealed appliance)
Hydraulics and controls
- Circulator works
- Thermostat talks to the boiler
- Valves and air vents work, no leak
Safety
- Oil supply line and its valve tight, no leak
- Measuring ports sealed again
- Safety devices
The measurement
With the analyser, not by eye.
- Combustion analysed before and after the work
- CO, efficiency, flue gas temperature and smoke index
- Compared with the legal limits of your region
- The analyser's report kept as proof
- Ambient CO measured on arrival and in front of the appliance
Appliance servicing
- General condition checked: cleanliness, tightness, wear, operation
- Outdoor unit cleaned: evaporator, fan, condensate drain
- Filters cleaned
- Electrical connections and ducts checked
- Controls and parameters checked: heating curve, back-up heater
Hydraulics and controls
- Circulator works
- Valves and air vents work, no leak
- Sludge filter cleaned
Refrigerant circuit
- Refrigerant circuit tightness checked
- Logbook created and kept up to date
How it works
Your appliances
Tick one or more: one visit, the prices added up.
The moment
First the days our technician already comes near you. We confirm by e-mail.
The certificate
By e-mail after the visit, and in your customer area with the date of the next maintenance.
Good to know
Maintenance grant in Flanders
For modest incomes, up to €192 incl. VAT for servicing a gas or oil boiler. It ends on 01/01/2027.
6% VAT
Servicing and repairing a boiler stay at 6% VAT in a home over 10 years old.
A boiler 15 years or older?
3 out of 10 boilers we service are that old. We tell you frankly whether to keep or replace it.
Frequently asked questions
Let us schedule your next service
Choose your appliances and the moment online, or call us.