Not enough water or water pressure too low
Breakdown: the boiler is stopped
The boiler has no water or not enough: the heating system pressure is too low (below 0.5 bar on an ecoTEC plus), or the boiler no longer measures it correctly (pressure sensor, cable, pump). It is a safety shutdown: the boiler stops so as not to fire dry. On an aroTHERM, aroTHERM plus, aroTHERM pure, aroTHERM Split plus, versoTHERM plus or recoCOMPACT exclusive heat pump, F.22 also reports water pressure too low in the heating circuit (leak, air pocket or faulty pressure sensor): the heat pump stops, and on an aroTHERM VWL ../5 AS or aroTHERM plus VWL ../6 A the message clears as soon as the pressure is back above 0.5 bar.
What you can do
- Write down the code shown and the boiler or heat pump model (on the rating plate).
- On a boiler, check the water pressure on the display or the gauge. Too low? Top up with water, as your installer showed you.
- On a heat pump, read the water pressure on the display (System monitor or Information menu). To top up the water, call us.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.22?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a recognised installer
Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.
The variants of code F.22
The meaning depends on the boiler: find yours below.
There is no water, or not enough water, in the product, or the water pressure is too low.
Water pressure too low
Heating circuit water pressure too low
dry firing
Safety shutdown lack of water
Safety shutdown: lack of water
Appliance operating without water
The boilers that show this code
What our technician checks
- Filling the system and bleeding it
- Leaks in the appliance and the system
- The water pressure sensor, replaced if needed
- The cable to the pump and to the pressure sensor
- The heating pump
- The wiring harness
- The automatic filling loop and the internal expansion vessel