Skip to Content

Boiler-room renovation

The heart of the building, renewed.

Boilers, hot water, pumps, flue and controls: we renew the whole boiler room, from a house to an apartment building. In a co-ownership, in phases, with a proposal ready for the general meeting and the heating kept available.

3

phases and one point of contact: audit, general meeting, works

2 to 4

boilers in cascade: if one stops, the others keep heating

70 to 80%

of the yearly demand on the heat pump, in a hybrid boiler room

95 to 98 %

efficiency of a modern condensing boiler

An apartment building cut open: the boilers in the basement, the flue to the roof, and the pipes rising to the radiators and the hot water of every apartment.

How a collective boiler room works

One room in the basement heats every apartment and makes their hot water.

1

The boilers produce the heat

2 to 4 modular condensing boilers, sized on the demand, work together in cascade. If one stops, the others keep heating.

2

One header distributes it

A single hydraulic header sends the heating water to the risers of the building.

3

The risers carry it to each apartment

To the radiators, and to the kitchen and the bathroom for the hot water.

4

Each apartment counts its own

Individual metering per apartment can be added to every option: a fair split by actual consumption, mandatory in many recent renovations.

Cascade or hybrid?

What a renovation brings

  • Modern condensing boilers: 95 to 98% efficiency, and a cascade often fits in the existing boiler room
  • Redundancy: in a cascade, one boiler down does not leave the building in the cold
  • With a hybrid, a heat pump covers 70 to 80% of the yearly demand: a big CO2 gain, with the existing radiators
  • One point of contact from the audit to the maintenance, and a weekly progress update for the syndic

What we check at the audit

  • The envelope of the building, its age and the budget: they decide between a cascade and a hybrid.
  • The heat load and the energy profile of the building, to size the boilers and the heat pump.
  • The options with their investment and their running costs, side by side in one document.
  • In a co-ownership: the planning with the residents, so that hot water and heating stay available during the works.

Request a free visit

What we install

Mostly Buderus; Bosch and Vaillant case by case. The boilers, and everything around them that makes a clean and lasting boiler room.

Logamax plus GB272 · Logano plus KB372
For buildings, alone or in cascade

Logamax plus GB272 · Logano plus KB372

Power50 to 300 kW
FuelGas
MountingWall-hung or floor-standing
Efficiency95 to 98 %
Logamax plus GB192i.2
For the house

Logamax plus GB192i.2

Power15 to 45 kW
FuelGas
MountingWall-hung
Efficiency95 to 98 %

Our projects

Dynamic snippet

Subsidies and VAT

The heat pump of a hybrid boiler room is eligible for subsidies in 2026, collective heat pumps included, depending on the region. A gas boiler is at 21% VAT since 1 July 2025; the heat-pump part stays at 6% in a home over 10 years old. We calculate it and put it in the proposal.

Your renovation in four steps

1

Free visit and audit

On site: heat load, energy profile, options with investment and running costs, in one document.

2

Proposal for the general meeting

Planning, cost per apartment (an average: the split follows the shares of the basic deed), savings and subsidies. We come to present it.

3

Works in phases

Hot water and heating stay available during the changeover. The syndic receives a weekly progress update.

4

Start-up and maintenance

Start-up by our technicians, then maintenance and service by the same team.

Frequently asked questions

Will the residents be left without heating during the works?

No: we replace in phases, and hot water and heating stay available during the changeover. We plan with the residents, and the syndic receives a weekly progress update.

Cascade or hybrid: which one for our building?

It depends on the envelope, the age of the building and the budget. A cascade of condensing boilers is compact and redundant; a hybrid lets a heat pump cover 70 to 80% of the yearly demand. The audit compares both.

What does the proposal for the general meeting contain?

The planning, the cost per apartment (an average: the split between co-owners follows the shares of the basic deed), the energy savings and the subsidies. We come to present it at the meeting.

Can each apartment pay for its own consumption?

Yes: individual metering per apartment can be added to every option, for a fair split by actual consumption. It is mandatory in many recent renovation scenarios.

Which brands do you install?

Mostly Buderus (we are a System Partner), Bosch and Vaillant, chosen case by case for your building and your budget.

And for a house?

The same care at a smaller scale: boiler, hot water tank, pumps, expansion vessel and controls renewed together. Replacing the boiler alone usually takes one working day; we tell you at the visit how long the whole room will take.

How soon can you come?

The on-site visit is free and without commitment.

Which subsidies and which VAT?

The heat pump of a hybrid is eligible for subsidies in 2026, collective heat pumps included, depending on the region. A gas boiler is at 21% VAT since 1 July 2025; the heat-pump part stays at 6% in a home over 10 years old.

A house?

Free visit, clear quote, no commitment.

Request a free visit

A co-ownership?

Syndics and co-owners: a proposal ready for the general meeting, works in phases, one point of contact.

Learn more