Skip to Content
Repair
Vaillant Fault code Vaillant
F.42

Coding resistor fault

Breakdown: the boiler is stopped

The boiler does not recognise the coding resistor that tells it its model, output or gas type: short circuit, break, wrong resistor or an unsuitable wiring harness. It is a fault: the boiler no longer knows how to run and waits for a technician. On an aroTHERM, aroTHERM plus, aroTHERM pure, aroTHERM Split plus, versoTHERM plus or recoCOMPACT exclusive heat pump, F.42 also reports a coding resistor that is damaged, missing or not recognised, or a badly connected plug; here too our technician needs to step in.

What you can do

  1. Write down the code shown and the boiler or heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.42?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Vaillant

Choose a recognised installer

Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.

The variants of code F.42

The meaning depends on the boiler: find yours below.

F.042

The coding resistor (inside the wiring harness) or the gas group resistor

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7, aroTHERM Split plus VWL ../8.2 AS, aroTHERM VWL ../7.1 A, ../8.1 A, aroTHERM pure VWL ../7.2 AS
F.042

Error: coding resistor

Breakdown: the boiler is stopped aroTHERM VWL ../2 A, ../3 A
F.042

Fault: coding resistor

Breakdown: the boiler is stopped aroTHERM VWL ../5 AS, aroTHERM plus VWL ../6 A, recoCOMPACT exclusive VWL ../5, versoTHERM plus VWL ../5
F.42

Coding resistor fault

Breakdown: the boiler is stopped VCW /5-5, VCW /5-7, VKK /4, VKK /5
F.42

No valid value for the appliance variants

Breakdown: the boiler is stopped VK /1-5, turboVIT combi
F.42

Coding resistor short circuit

Breakdown: the boiler is stopped VUW /5-5
F.42

Coding resistor fault (possibly in conjunction with F.70)

Breakdown: the boiler is stopped VCC /4
F.42

Incorrect value for the appliance model

Breakdown: the boiler is stopped VSC /2

The boilers that show this code

What our technician checks

  • The coding resistor, how it is fitted and its connector
  • The earth connection and the cable
  • The harness to the fan and its connectors
  • The part number of the harness to the gas valve or heat cell
  • ecoTEC exclusive: the gas type selected in parameter D.087
  • aroTHERM VWL ../7.1 A, ../8.1 A: the fan, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.