Vaillant Fault code Vaillant
F.86

External safety contact open (underfloor heating)

Breakdown: the boiler is stopped

A safety contact connected to the appliance, for example the underfloor heating safety thermostat, has opened: on the boiler it cuts the burner (on the ecoTEC plus VC 206/8-5 the code also covers the flow sensor, the 3-way valve and the condensate pump); on an aroTHERM (VWL ../2 A, ../3 A), flexoTHERM exclusive or flexoCOMPACT exclusive heat pump the floor is too hot, the heating circuit flow rate too low, the underfloor heating circuit closed or the maximum thermostat wrongly set. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service; the heat pump no longer works normally (depending on the fault, it may keep running in emergency mode).

What you can do

  1. Write down the code shown and the boiler or heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.86?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Vaillant

Choose a recognised installer

Ecowatt is a Vaillant installer: our group is on Vaillant's official list of installers.

The variants of code F.86

The meaning depends on the boiler: find yours below.

F.086

Thermostat open

Breakdown: the boiler is stopped aroTHERM VWL ../2 A, ../3 A
F.086

Bldg circuit: lockout contact S20 open

Breakdown: the boiler is stopped flexoTHERM exclusive VWF ../4
F.86

Fault, external safety shutdown

Breakdown: the boiler is stopped VC /8-5
F.86

Underfloor heating contact open (burner off input)

Breakdown: the boiler is stopped VUW /5-5
F.86

Fault: floor contact

Breakdown: the boiler is stopped VCC /4

What our technician checks

  • The underfloor heating safety thermostat: setting and heating set point
  • The flow temperature sensor
  • The 3-way valve (sticking)
  • The condensate pump, replaced if faulty
  • The heating circuit flow rate and the underfloor heating circuit valves (open)
  • The S20 contact on the flexoTHERM main PCB (HMU)