Flame lost too often
Breakdown: the boiler is stopped
The burner flame has gone out too many times. For safety, the boiler locks out and only restarts after a reset.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that the boiler's gas shutoff valve is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 2951?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 2951
The meaning depends on the boiler: find yours below.
Too many flame losses
The boilers that show this code
What our technician checks
- The gas shutoff valves (main and appliance) and the gas line
- Ionization operation and the ground connection (PE) in the control unit
- The ignition and monitoring electrodes, their cables and their connector, replaced if necessary
- The burner setting, also at minimum load, or its nozzles
- The gas valve, replaced if necessary
- The flue gas exhaust and the combustion air supply (ventilation opening)
- The heat exchanger on the flue gas side, cleaned
- The control unit or the burner control unit, replaced if necessary