276
Heating water too hot (over 95 °C)
Information: nothing to do
The flow temperature sensor measures heating water above 95 °C. This message can appear without any fault, when all the radiator valves close at the same time.
What you can do
- Check the water pressure: at least 1 bar, or the needle in the green zone of the pressure gauge. Too low? Top up with the boiler cold, the way your installer showed you.
- Check that enough radiators are open.
- Bleed the radiators.
- Does the code stay on or come back? Do not take anything apart: call us.
Nothing to do
This message belongs to the boiler's normal operation.
Call usChoose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 276
The meaning depends on the boiler: find yours below.
276
The temperature at the flow temperature sensor is > 95 °C
Information: nothing to do
GB192i
The boilers that show this code
What our technician checks
- The system water pressure
- The isolation valves, open
- The pump: continuous running in the function test, connection cable, start-up; replaced if necessary
- The setting of the pump output or pump curve
- The flow temperature sensor and its cable (open circuit, short circuit)