System water pressure too high
Breakdown: the boiler is stopped
The water pressure in the heating system is too high. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.87?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.87
The meaning depends on the boiler: find yours below.
System overpressure
What our technician checks
- Lowering the pressure to the permitted value (drain and refill if the message returns after 10 s)
- The system pressure, measured with an external gauge
- The expansion vessel and its pre-charge, replaced if needed
- The water pressure sensor: connection and deviation from an external gauge (above 10 %, replaced)
- Blockages of the non-return valves
- The safety group, replaced if needed