Air pressure switch or flow sensor fault
Breakdown: the boiler is stopped
On a Vitopend 100-W WH1D and a Vitodens 200 WB2A, the air pressure switch, which monitors the air intake and the flue, does not react as expected when the burner starts: the burner locks out and the boiler only starts again after a reset; on a Vitodens 100-W WB1A the air pressure switch is faulty and the burner stays blocked until it is repaired. On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF), F.5 means a fault in the water flow sensor: the boiler keeps running normally, on a substitute value.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Vitopend 100-W WH1D and Vitodens 200 WB2A only: reset the boiler once only.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F5?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F5
The meaning depends on the boiler: find yours below.
open circuit of the flow rate sensor
The air pressure switch does not open when the burner starts or does not close when the…
Air pressure switch faulty
The air pressure switch is not open when the burner starts
What our technician checks
- Vitopend 100-W WH1D: the flue and air intake duct
- The air pressure switch, its hoses and connecting cables
- Vitodens 200 WB2A: the fan, its connecting cables, its power supply and its control
- Vitodens One Base: plug 33/X6 and the cable between the BCU burner control unit and the flow sensor
- Vitodens One Base: the flow sensor, replaced if the message persists, then the BCU burner control unit