Skip to Content
Repair
Viessmann Fault code Viessmann
F.342

Burner control unit communication fault

Blocking: it retries by itself

The boiler's central electronic module (HMU) no longer communicates with the burner control unit (BCU) over the internal CAN bus. The boiler no longer heats the rooms or the hot water until our technician has restored the link.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.342?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.342

The meaning depends on the boiler: find yours below.

F.342

Communication fault of the burner control unit

Blocking: it retries by itself Vitodens One Base

What our technician checks

  • Switching the appliance off for at least 2 minutes
  • The internal CAN bus cable between the HMU (plug X4) and the BCU (plug X4)
  • Seating of plugs and wires, contact corrosion and cable condition
  • With F.142: the HMU electronic module, replaced if needed
  • Without F.142: the BCU tested with only plugs X2, X4, X16 and X18, replaced if F.342 persists
  • The CAN bus participants reconnected one by one, and the faulty cable or participant replaced

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.