Flame signal too high during calibration
Breakdown: the boiler is stopped
During the automatic calibration of its combustion, shortly after the burner starts, the boiler measures a flame signal (ionisation current) that is too high: the electrode is not at the right distance from the burner, or the combustion air carries dust or substances that foul the electrodes. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
- Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.
Does your boiler show E1?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E1
The meaning depends on the boiler: find yours below.
Ionisation current too high during calibration
What our technician checks
- The distance between the ionisation electrode and the burner grid
- Dust in the combustion air (building work, open-flue operation)
- The source of deposits on the electrodes in the boiler room and flue system (detergents, cleaning or personal care products)
- After replacing the burner grid and the electrode: cleaning the fan unit, the gas-air duct and the Venturi extension