Internal extension H1/H2 short to earth
Breakdown: the boiler is stopped
On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB, the internal extension H1 or H2 of the control, its cables or its plugs touch an earthed part (short to earth): the burner stops and may lock out. On a Vitodens 100-W B1HF, code 75 reports that the heating water is not circulating (no flow) and the system goes to fault; in both cases the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Vitodens 100-W B1HF: check the system pressure on the display. Below 1.0 bar, top up with water or call us.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 75?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 75
The meaning depends on the boiler: find yours below.
Short circuit to earth of the internal extension H1/H2
No flow rate
What our technician checks
- The internal extension H1/H2, its cables and its plugs: no contact with an earthed part
- The reset with the R key, once the contact is cleared
- Topping up the water and venting the system (Vitodens 100-W B1HF)
- The fill and drain taps, open (Vitodens 100-W B1HF)
- The flow sensor, if fitted (Vitodens 100-W B1HF)
- The circulation pump, replaced if needed (Vitodens 100-W B1HF)