Viessmann Fault code Viessmann
477

Solar temperature difference fault

Blocking: it retries by itself

The controller finds that the temperature difference between the solar collectors and the hot water cylinder is out of tolerance: air in the solar circuit, a badly placed sensor or a faulty pump can be the cause. The boiler keeps running, but the solar system only works in a limited way and no longer delivers solar heat.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 477?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 477

The meaning depends on the boiler: find yours below.

477

Temperature differential monitoring error solar collector/storage tank, difference outside tolerance

Blocking: it retries by itself Vitodens 100-W B1HF

What our technician checks

  • The flow in the solar circuit (none or too low) and its setting
  • Air and dirt in the solar circuit
  • The system pressure
  • The operation of the non-return valves
  • The circulation pump: operation, rated speed and soiling
  • The safety temperature limiter, if fitted
  • The connections and plugs of sensors TS1 (cylinder) and TS2 (collector) on the ADIO module (EM-S1)
  • The resistance of sensors TS1 (NTC 10 kΩ) and TS2 (NTC 20 kΩ), plug removed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.