No ignition spark
Breakdown: the boiler is stopped
When the burner starts, the ignition gives no spark: the burner cannot light. The burner locks out and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 359?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 359
The meaning depends on the boiler: find yours below.
No ignition spark
What our technician checks
- The insulation of the ignition electrode (damage)
- The 230 V supply at the igniter during the ignition phase; without it, the HBMU central electronic module to be replaced
- The igniter, to be replaced if it gets 230 V and the fault still occurs
- The connection and link cables of the igniter and the ignition electrode