Viessmann Fault code Viessmann
29

Sensor open circuit: low-loss header or return

Blocking: it retries by itself

On a Vitodens 100-W B1HF, the temperature sensor of the low-loss header (the separator between the boiler and the heating circuits) is open circuit: the boiler keeps regulating, but without that sensor. With a Vitotronic 200 KW2 or 300 KW3 control, it is the return sensor that is open circuit (on the KW3, the one of heating circuit M1): the control carries on without taking the return temperature into account, and in both cases our technician needs to repair the sensor.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 29?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 29

The meaning depends on the boiler: find yours below.

29

Open circuit of the low loss header sensor

Blocking: it retries by itself Vitodens 100-W B1HF
29

Open circuit return sensor

Blocking: it retries by itself Vitotronic 200 KW2
29

Open circuit return sensor heating circuit M1

Blocking: it retries by itself Vitotronic 300 KW3

What our technician checks

  • The low-loss header setting in the commissioning wizard (Vitodens 100-W B1HF)
  • The flow temperature sensor of the low-loss header (Vitodens 100-W B1HF)
  • The voltage at the electronic module's sensor input: 3.3 V with the sensor disconnected (Vitodens 100-W B1HF)
  • The return sensor (Vitotronic 200 KW2; circuit M1 on the Vitotronic 300 KW3)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.