Sensor open circuit: low-loss header or return
Blocking: it retries by itself
On a Vitodens 100-W B1HF, the temperature sensor of the low-loss header (the separator between the boiler and the heating circuits) is open circuit: the boiler keeps regulating, but without that sensor. With a Vitotronic 200 KW2 or 300 KW3 control, it is the return sensor that is open circuit (on the KW3, the one of heating circuit M1): the control carries on without taking the return temperature into account, and in both cases our technician needs to repair the sensor.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 29?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 29
The meaning depends on the boiler: find yours below.
Open circuit of the low loss header sensor
Open circuit return sensor
Open circuit return sensor heating circuit M1
What our technician checks
- The low-loss header setting in the commissioning wizard (Vitodens 100-W B1HF)
- The flow temperature sensor of the low-loss header (Vitodens 100-W B1HF)
- The voltage at the electronic module's sensor input: 3.3 V with the sensor disconnected (Vitodens 100-W B1HF)
- The return sensor (Vitotronic 200 KW2; circuit M1 on the Vitotronic 300 KW3)