Return sensor open or no water
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:07), the return temperature sensor is open-circuit; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E07), there is not enough water in the boiler or the pump is not running (pressure too low, no circulation, air in the system). In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On an Avanta or Aquanta: check the water pressure; below 1 bar, top up with water as the user manual explains.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:07?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:07
The meaning depends on the boiler: find yours below.
Water pressure in the boiler: absent
No water in the boiler or pump stopped
No water in the boiler or the pump does not turn
Return temperature sensor open
Open circuit in the return temperature sensor
Return temperature sensor circuit open
The boilers that show this code
What our technician checks
- The return sensor wiring (E:07)
- How the sensor is fitted and works, replaced if needed (E:07)
- The water pressure and any leaks (E07)
- The circulating pump: shaft freed with a screwdriver, wiring, replaced if it still does not run (E07)
- Bleeding the air from the boiler and the system (E07)
- The pump wiring and electrical connections (Avanta Plus, Avanta Platinum Plus)