Sensor, hot water or hydraulic setting fault
Breakdown: the boiler is stopped
On a Logano plus KB192i, KB192i.2 or GB212 boiler, A01 is a locking fault: faulty outdoor sensor or hot water sensor, hot water that stays cold, or an unsupported hydraulic configuration, and the number shown next to it (800, 808, 810 or 845) tells which one. On a Logatherm or Bosch Compress heat pump (HMC300, HMC310 or HPC410 control), the number next to it also tells what it is about: hot water thermal disinfection failed (811), defrost fault (5378, and 5526 on the HMC300), indoor and outdoor units that do not match (5522), blocked condensate drain (5450, 5454) or maintenance due (5451) on the HMC300, or, on the HMC310 and HPC410, a message from the outdoor unit about its compressor, its power supply or its refrigerant circuit (5800 to 5829). The heat pump keeps heating as far as possible; if the same fault locks the outdoor unit, code H01 is shown instead.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Heat pump with an HMC300 control, number 5450 or 5454: clean the condensate drain (leaves, soil).
- Heat pump with an HMC300 control, number 5526: clean the outdoor unit, especially the evaporator.
- Heat pump with an HMC300 control, number 5451: the heat pump is due for maintenance; call us to book it.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show A01?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code A01
The small number shown beside the code tells which.
Outdoor unit defrost fault
Z1 Condensate drain blocked
Heat pump maintenance required
Z2 Condensate drain blocked
The indoor and outdoor units do not match
Z2 Defrost failed
Outdoor unit controller restarted
Outdoor unit CAN gateway restarted
No power supply at compressor
Current sensor fault
IPM driver pin fault
AC input zero cross error
Compressor current sensor fault
Compressor driver pin fault
PFC current sensor fault
PFC over current fault
Compressor PFC over current fault
Compressor Overcurrent
Compressor lock undefined driver fault
Low evaporating temperature in cooling
Compressor cannot start
Outdoor unit coil overheating
Low pressure in refrigerant circuit
Outdoor unit heat sink overheating in standby mode
Unspecified outdoor unit fault
High evaporating temperature in cooling (faulty reverse valve)
The outdoor temperature sensor is faulty
DHW temp. sensor 1 faulty. Deactivate the DHW function if necessary.
The domestic hot water stays cold
Domestic hot water production: thermal disinfection failed
The hydraulic configuration is not supported
The boilers that show this code
What our technician checks
- The connection, cable and mounting of the sensor (outdoor or cylinder)
- The sensor resistance, compared with its characteristic curve
- A leak or constant hot water draw, and the cylinder charging pump
- The configuration of the hot water, heating circuit 1 and the system pump on the module
- Defrosting: a dirty outdoor unit, thermostats open in the system and the TL2 sensor checked against its table (heat pump, 5378 and 5526)
- The indoor and outdoor unit combination, and the rotary coding switch setting of a replaced I/O or installer module (5522)
- The compressor wiring, connections, internal resistances and drive, and the stability of the power supply (5800 to 5827)
- The refrigerant circuit: isolation valves open, refrigerant leak or blockage, 4-way valve and ICT sensor (5818 to 5829)