Temperature sensor open or short-circuited
Breakdown: the boiler is stopped
E33 means a fault of the domestic hot water sensor: an open circuit on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), a short circuit of the NTC3 sensor on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller); on a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, it means that the NTC3 sensor is open. In every case the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E33?
Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E33
The meaning depends on the boiler: find yours below.
NTC3 short circuit
NTC3 open
DHW sensor open
What our technician checks
- The sensor concerned, its connection and wiring: open circuit or short circuit
- The sensor or its wiring, replaced if needed
- Restarting the boiler once the repair is done (ACVMax)