Skip to Content
Repair
ACV Fault code ACV
E33

Temperature sensor open or short-circuited

Breakdown: the boiler is stopped

E33 means a fault of the domestic hot water sensor: an open circuit on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), a short circuit of the NTC3 sensor on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller); on a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, it means that the NTC3 sensor is open. In every case the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E33?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E33

The meaning depends on the boiler: find yours below.

E33

NTC3 short circuit

Breakdown: the boiler is stopped MCBA
E33

NTC3 open

Breakdown: the boiler is stopped ESYS
E33

DHW sensor open

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • The sensor concerned, its connection and wiring: open circuit or short circuit
  • The sensor or its wiring, replaced if needed
  • Restarting the boiler once the repair is done (ACVMax)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.