Skip to Content
Repair
ACV Fault code ACV
E01

Ignition failure after five attempts

Breakdown: the boiler is stopped

The boiler has tried five times to light its burner without getting a flame. It is a fault: the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Check the gas supply to the boiler: it must be turned on.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E01?

Repair visit: 360 € excl. VAT (381.60 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E01

The meaning depends on the boiler: find yours below.

E01

No flame presence signal after five start attempts

Breakdown: the boiler is stopped ESYS
E01

Ignition failure

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • The gas supply to the appliance and gas reaching the burner
  • The ignition cable and its connection
  • The electrode: condition, position and gap
  • The 24 V wiring (short circuit) (ESYS)
  • The gas valve and its electrical connection

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.